Skip to main content
Glama

Modbus MCP Server

An MCP server that standardizes and contextualizes Modbus data, enabling seamless integration of AI agents with industrial IoT systems.

GitHub License Python Version Status

Features

  • Modbus Tools:

    • Read/write holding registers (read_register, write_register).

    • Read/write coils (read_coils, write_coil).

    • Read input registers (read_input_registers).

    • Read multiple holding registers (read_multiple_holding_registers).

  • Prompt: Analyze Modbus register values with a customizable prompt (analyze_register).

  • Flexible Connections: Supports Modbus over TCP, UDP, or serial, configured via environment variables.

Related MCP server: Industrial MCP

Requirements

  • Python: 3.10

  • uv for dependency and virtual environment management.

Installation

  1. Install uv:

    curl -LsSf https://astral.sh/uv/install.sh | sh
  2. Clone the Repository:

    git clone https://github.com/kukapay/modbus-mcp.git
    cd modbus-mcp
  3. Install Dependencies:

    uv sync

Configuration

The server connects to a Modbus device using parameters specified via environment variables. Set these variables in a .env file or your shell environment.

Environment Variables

Variable

Description

Default

Required

MODBUS_TYPE

Connection type: tcp, udp, or serial

tcp

Yes

MODBUS_HOST

Host address for TCP/UDP

127.0.0.1

For TCP/UDP

MODBUS_PORT

Port for TCP/UDP

502

For TCP/UDP

MODBUS_DEFAULT_SLAVE_ID

Slave ID

1

For TCP/UDP

MODBUS_SERIAL_PORT

Serial port (e.g., /dev/ttyUSB0, COM1)

/dev/ttyUSB0

For serial

MODBUS_BAUDRATE

Serial baud rate

9600

For serial

MODBUS_PARITY

Serial parity: N (none), E (even), O (odd)

N

For serial

MODBUS_STOPBITS

Serial stop bits

1

For serial

MODBUS_BYTESIZE

Serial byte size

8

For serial

MODBUS_TIMEOUT

Serial timeout (seconds)

1

For serial

Example .env File

For TCP:

MODBUS_TYPE=tcp
MODBUS_HOST=192.168.1.100
MODBUS_PORT=502
MODBUS_SLAVE_ID=1

For Serial:

MODBUS_TYPE=serial
MODBUS_SERIAL_PORT=/dev/ttyUSB0
MODBUS_BAUDRATE=9600
MODBUS_PARITY=N
MODBUS_STOPBITS=1
MODBUS_BYTESIZE=8
MODBUS_TIMEOUT=1

Usage

Installing for Claude Desktop

The configuration file:

{
   "mcpServers": {
       "Modbus MCP Server": {
           "command": "uv",
           "args": [ "--directory", "/path/to/modbus-mcp", "run", "modbus-mcp" ],
           "env": { "MODBUS_TYPE": "tcp", "MODBUS_HOST": "127.0.0.1", "MODBUS_PORT": 502 },
       }
   }
}

Using Tools

Note: Natural language support depends on the client’s ability to parse and map prompts to tools. The MCP Inspector requires structured JSON, but the examples below show how conversational inputs translate.

  1. Read a Holding Register:

    • Prompt:

      Please read the value of Modbus holding register 0.
    • MCP Inspector JSON:

      {
        "tool": "read_register",
        "parameters": {"address": 0, "slave_id": 1}
      }
    • Expected Output: Value: <register_value>

  2. Write to a Holding Register:

    • Prompt:

      Set Modbus holding register 10 to the value 100.
    • MCP Inspector JSON:

      {
        "tool": "write_register",
        "parameters": {"address": 10, "value": 100, "slave_id": 1}
      }
    • Expected Output: Successfully wrote 100 to register 10

  3. Read Coils:

    • Prompt:

      Check the status of the first 5 Modbus coils starting at address 0.
    • MCP Inspector JSON:

      {
        "tool": "read_coils",
        "parameters": {"address": 0, "count": 5, "slave_id": 1}
      }
    • Expected Output: Coils 0 to 4: [False, False, False, False, False]

  4. Write to a Coil:

    • Prompt:

      Turn on Modbus coil 5.
    • MCP Inspector JSON:

      {
        "tool": "write_coil",
        "parameters": {"address": 5, "value": true, "slave_id": 1}
      }
    • Expected Output: Successfully wrote True to coil 5

  5. Read Input Registers:

    • Prompt:

      Read the values of 3 Modbus input registers starting from address 2.
    • MCP Inspector JSON:

      {
        "tool": "read_input_registers",
        "parameters": {"address": 2, "count": 3, "slave_id": 1}
      }
    • Expected Output: Input Registers 2 to 4: [<value1>, <value2>, <value3>]

  6. Read Multiple Holding Registers:

    • Prompt:

      Get the values of Modbus holding registers 0 through 2.
    • MCP Inspector JSON:

      {
        "tool": "read_multiple_holding_registers",
        "parameters": {"address": 0, "count": 3, "slave_id": 1}
      }
    • Expected Output: Holding Registers 0 to 2: [<value1>, <value2>, <value3>]

License

This project is licensed under the MIT License. See LICENSE for details.

Tool Schema Changelog

Recent tool additions, removals, and schema changes observed during successful MCP inspections. Dates show when Glama detected each change.

No tool schema history has been recorded yet.

Maintenance

ActivityInactive
ResponsivenessNo issues

Resources

Unclaimed servers have limited discoverability.

Looking for Admin?

If you are the server author, to access and configure the admin panel.

Related MCP Connectors

Related MCP Servers

  • A
    license
    Not graded
    quality
    D
    maintenance
    An open-source MCP server that bridges AI models with industrial equipment, supporting multiple protocols like Modbus, OPC UA, and MQTT for reading data and controlling machines.
    2
    Apache 2.0
  • A
    license
    Not graded
    quality
    B
    maintenance
    MCP server for Modbus RTU/TCP instrument control, enabling query and write operations on Modbus registers through a standardized interface, supporting both standalone use and integration with lab-executor.
    MIT

Latest Blog Posts

MCP directory API

We provide all the information about MCP servers via our MCP API.

curl -X GET 'https://glama.ai/api/mcp/v1/servers/kukapay/modbus-mcp'

If you have feedback or need assistance with the MCP directory API, please join our Discord server